The CX8091 is a control system with a switched Ethernet port. It supports the BACnet and OPC UA protocols. K-bus or E-bus terminals can be attached as required; the CX8091 automatically recognises the type of I/O system connected during the start-up phase. The control system is programmed with TwinCAT via the fieldbus interface or the additional Ethernet interface. BACnet (Building Automation Control Network) is a standardised, manufacturer-independent communication protocol for building automation. Areas of application include HVAC, lighting control, safety and fire alarm technology. The TwinCAT OPC UA Server provides the functionality of the OPC Unified Architecture (UA) specification. In addition to data access techniques UA also specifies the data coding and the transport protocols.

The CX8095 is a control system with EtherNet/IP slave interface. The EtherNet/IP interface is designed as a 2-port switch for realisation of daisy-chain cabling. K-bus or E-bus terminals can be attached as required; the CX8095 automatically recognises the type of I/O system connected during the start-up phase. The control system is programmed with TwinCAT via the fieldbus interface or the additional Ethernet interface.

 

The CX8093 is a control system with PROFINET RT device interface. The PROFINET interface is designed as a 2-port switch for realisation of daisy-chain cabling. K-bus or E-bus terminals can be attached as required; the CX8093 automatically recognises the type of I/O system connected during the start-up phase. The control system is programmed with TwinCAT via the fieldbus interface or the additional Ethernet interface.

 

The CX8090 is a control system with a switched Ethernet port. It supports protocols such as real-time Ethernet, ADS UDP/TCP, Modbus TCP client/server or open TCP/IP-UDP/IP communication. K-bus or E-bus terminals can be attached as required; the CX8090 automatically recognises the type of I/O system connected during the start-up phase. The control system is programmed with TwinCAT via the fieldbus interface or the additional Ethernet interface.

 

The CX8051 is a control system with CANopen slave interface. The CANopen address is set via two rotary selection switches. The CX8051 offers automatic baud rate detection. K-bus or E-bus terminals can be attached as required; the CX8051 automatically recognises the type of I/O system connected during the start-up phase. The control system is programmed via the fieldbus interface or the additional Ethernet interface.

 

The CX8031 is a control system with PROFIBUS slave interface. The PROFIBUS address is set via two rotary selection switches. The CX8031 offers automatic baud rate detection. K-bus or E-bus terminals can be attached as required; the CX8031 automatically recognises the type of I/O system connected during the start-up phase. The control system is programmed with TwinCAT via the fieldbus interface or the additional Ethernet interface.

The CX8010 is a control system with EtherCAT slave interface, to which optional K-bus or E-bus terminals can be attached. The CX8010 automatically recognises the type of I/O system connected during the start-up phase. The control system is programmed with TwinCAT via the fieldbus interface or the additional Ethernet interface. The DIP switch enables fixed or automatic addressing in the EtherCAT network.