KL9187 | Potential distribution terminal, 8 x 0 V

The feed terminals can be inserted anywhere between the input and output terminals in order to construct a further potential group, or in order to supply the terminals that follow to the right with additional current. The feed terminals can be used for voltages up to 230 V AC. The terminals with diagnostics report any voltage failure or short-circuit to the controller. The function and electronic data from the diagnostic terminals appear like a 2-channel input terminal with correlating voltage. In other words, they occupy 2 bits in the automation device’s process image.

 

Infeed via Bus Coupler only,
one potential group

Infeed via Bus Coupler and incoming feeder terminal, three potential groups

Technical data KL91xx | KS91xx, KL92xx
Power contacts max. 10 A
Short-circuit-proof 125 A
Voltage 24 V DC or 230 V AC, depending on type
Protect. class/installation pos. IP 20/variable
Pluggable wiring for all KSxxxx Bus Terminals
Special terminals
KL9210-0020 with 2 A fuse (slow-blow) and modified label

Bus function terminals

The power feed terminals make it possible to set up various potential groups with any desired voltages (KL9190) or with the standard voltages of 24 V DC or 230 V AC (120 V AC). The power feed terminals are available with or without fine-wire fuse. In order to monitor the supply voltage, the terminals with diagnostics report the status of the power feed terminal to the Bus Coupler through two input bits. It is thus possible for the controller to check the distributed peripheral voltage over the fieldbus. The operating point performance conforms to the input terminals KL1002 (24 V) and KL1702 (230 V).

The KL9180, KL9185 and KL9195 Bus Terminals allow the supply voltage to be accessed a number of times via spring force terminals. These Bus Terminals make it unnecessary to use additional terminal blocks on the terminal strip. The KL9195 Bus Terminal can be used for the connection of screens. The KL9195 connects the spring force contacts directly to the DIN rail, and can optimally ground incoming electromagnetic radiation. The two power contacts are looped through by the KL9195, allowing two wires to be connected to each power contact. The KL9010 bus end terminal is necessary for data exchange between the Bus Coupler and the Bus Terminals. Each assembly must be terminated at the right hand end with a KL9010 bus end terminal. The bus end terminal does not have any other function or connection facility. The KL9080 is used to identify potential groups (e.g. 230 V AC/24 V DC). It is inserted between two potential groups, and indicates the separation through an orange coloured cover.

Meaning of the diagnostic bits:
Bit 0 = 0 no power supply present,
Bit 0 = 1 power supply present,
if the bus function terminal does not have a fuse, then bit 1 = 0.
Technical data KL9190 | KS9190
KL9100 | KS9100
KL9110 | KS9110
KL9150 | KS9150
KL9160 | KS9160
Nominal voltage arbitrary 24 V DC 24 V DC 230 V AC (120 V AC) 230 V AC (120 V AC)
Integrated fine-wire fuse
Diagnostics yes yes
Power LED green green green green
Defect LED
Reported to K-bus yes yes
PE contact yes
Shield connection
Renewed infeed yes
Connection facility to additional power contact 1
K-bus, looped through yes
Bit width in the process image 0 0 2 0 2
Connection to DIN rail
Electrical isolation yes
Housing width in mm 12
Side by side mounting on Bus Terminals with power contact yes
Side by side mounting on Bus Terminals without power contact yes
Pluggable wiring for all KSxxxx Bus Terminals
Meaning of the diagnostic bits:
Bit 0 = 0  no power supply present,
Bit 0 = 1  power supply present,
Bit 1 = 0  Fuse o.k.,
Bit 1 = 1  Fuse faulty.
Technical data KL9200
(KL9290)
KL9210 KL9250 KL9260
Nominal voltage 24 V DC (arbitrary) 24 V DC 230 V AC 230 V AC
Integrated fine-wire fuse …6.3 A …6.3 A …6.3 A …6.3 A
Diagnostics yes yes
Power LED green (without) green green green
Defect LED red (without) red red red
Reported to K-bus yes yes
PE contact yes yes yes yes
Shield connection
Renewed infeed yes yes yes yes
Connection facility to additional power contact 1 1 1 1
K-bus, looped through yes yes yes yes
Bit width in the process image 0 2 0 2
Connection to DIN rail
Electrical isolation yes yes yes yes
Housing width in mm 12
Side by side mounting on Bus Terminals with power contact yes yes yes yes
Side by side mounting on Bus Terminals without power contact yes yes yes yes
Pluggable wiring for all KSxxxx Bus Terminals
Meaning of the diagnostic bits:
Bit 0 = 0  no power supply present,
Bit 0 = 1  power supply present,
Bit 1 = 0  Fuse o.k.,
Bit 1 = 1  Fuse faulty.
Technical data KL9180
(KS9180)
KL9185
(KS9185)
KL9195
(KS9195)
KL9010
KL9080
Nominal voltage arbitrary up to 230 V AC arbitrary up to 230 V AC arbitrary up to 230 V AC end/separa. terminal
Integrated fine-wire fuse
Diagnostics
Power LED
Defect LED
Reported to K-bus
PE contact yes
Shield connection 2
Renewed infeed
Connection facility to additional power contact 2 4 1
K-bus, looped through yes yes yes –/yes
Bit width in the process image 0 0 0 0
Connection to DIN rail  13; shield terminal
Electrical isolation
Housing width in mm 12
Side by side mounting on Bus Terminals with power contact yes only 2 power contacts only 2 power contacts yes
Side by side mounting on Bus Terminals without power contact yes
Pluggable wiring for all KSxxxx Bus Terminals